... fire rated gypsum board 1⁄2 inch fire retardant treated plywood 5 % inch exterior plywood 1/4 inch asbestos board . All these materials , except plywood , are easily damaged by impact , so they should be installed on a rigid backing ...
... fire rated gypsum board 1⁄2 inch fire retardant treated plywood 5 % inch exterior plywood 1/4 inch asbestos board . All these materials , except plywood , are easily damaged by impact , so they should be installed on a rigid backing ...
Page 8
... fire extinguisher for wood , hay etc. A minimum 10 gallon per minute ( gpm ) at 30 psi is needed for limited fire - fighting ; 20 gpm at 60 psi is preferred . A washbasin is desirable for washing hands after doing work in the shop . If ...
... fire extinguisher for wood , hay etc. A minimum 10 gallon per minute ( gpm ) at 30 psi is needed for limited fire - fighting ; 20 gpm at 60 psi is preferred . A washbasin is desirable for washing hands after doing work in the shop . If ...
Page 26
... fires as well as oil and grease fires . Do not use water on oil or grease fires , since it can spread this type of fire . Fire extinguishers should be readily accessible near entrance doors and welding areas . A B C A B C Protective ...
... fires as well as oil and grease fires . Do not use water on oil or grease fires , since it can spread this type of fire . Fire extinguishers should be readily accessible near entrance doors and welding areas . A B C A B C Protective ...
Contents
Utilities | 6 |
Storage of Materials Tools and Parts | 14 |
Equipment and Power Hand Tool Specifications | 20 |
1 other sections not shown
Common terms and phrases
½ inch 12 inches A-FRAME STORAGE Agricultural Engineering air compressor aluminum amperes anvil arc welder arc welding Bench grinder blacksmith vise blade Bolt Building Frames capacity ceiling clamp clearance Cornell University drain drill press electric arc equipment feet Figure fire floor plan fluorescent fixtures foot foot length gauge grease grid frame grinding hangers HEAVY DUTY GRINDER hoist hose inch by 16ths installed insulation length letter code materials Metalworking minimum motor mounted Number Tools operator space outlets pair pipe vise placed pliers plywood portable power factor corrected radial arm saw recommended Sabre saw Scratch awl Screw drivers sealed ball bearings service area sheet metal side sizes Socket wrenches space may overlap space requirements spot lighting steel stored structural table saw tank template tool storage Tools and Specifications trusses tube wall welding area welding table wheel wide width wood woodworking vise workpiece space