" ... works which concern the manufacture of the splice bars ordered. The manufacturer shall afford the inspector, free of cost, all reasonable facilities to satisfy him that the splice bars are being furnished in accordance with these specifications. All... "
Railway Age Gazette - Page 17
1913
Full view - About this book

Report of Proceedings of the ... Annual Convention of the ..., Volume 50

American Railway Master Mechanics' Association - Railroad engineering - 1918 - 678 pages
...manufacturer shall afford the inspector, free of cost, all reasonable facilities to satisfy him that the tubes are being furnished in accordance with these specifications. All tests (except check analysis of steel tubes) and inspection shall be made at the place of manufacture prior to shipment,...
Full view - About this book

Bulletin, Volume 20, Part 1

American Society for Testing Materials - Building materials - 1920 - 868 pages
...irilpector, free of cost, all reasonable facilities to satisfy him that the material is being furnished in accordance with these specifications. All tests...Unless otherwise specified, any rejection based on Rejection, tests made in accordance with Section 5, shall be reported within five working days from...
Full view - About this book

Year-book

Building materials - 1913 - 420 pages
...while work on the contract of the purchaser is being performed, to all parts of the manufacturer's works which concern the manufacture of the splice...check analyses) and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not...
Full view - About this book

Structural Engineers' Handbook: Data for the Design and Construction of ...

Milo Smith Ketchum - Bridges, Iron and steel - 1914 - 956 pages
...manufacturer shall afford the inspector, free of cost, all reasonable facilities to satisfy him that the bars are being furnished in accordance with these...check analyses) and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not...
Full view - About this book

Report of Proceedings of the ... Annual Convention of the ..., Volume 47

American Railway Master Mechanics' Association - Railroad engineering - 1914 - 886 pages
...manufacturer shall afford the inspector, free of cost, all reasonable facilities to satisfy him that the tubes are being furnished in accordance with these specifications....check analyses and inspection shall be made at the place of manufacture prior to shipment unless otherwise specified, and are to be so conducted as not...
Full view - About this book

Structural Engineers' Handbook: Data for the Design and Construction of ...

Milo Smith Ketchum - Building, Iron and steel - 1914 - 926 pages
...free of cost, all reasonable facilities to satisfy him that the bars are being furnished in :ordance with these specifications. All tests (except check analyses) and inspection shall be ide at the place of manufacture prior to shipment, unless otherwise specified, and shall be so nducted...
Full view - About this book

Rails and Fastenings, 1916

Lackawanna Steel Company - Rail fastenings - 1915 - 170 pages
...of this marking shall appear on each finished splice bar. VI. INSPECTION AND REJECTION Inspection: 15. The inspector representing the purchaser shall...check analyses) and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not...
Full view - About this book

The Design of Steam Boilers and Pressure Vessels

George Bartholomew Haven, George Wright Swett - Pressure vessels - 1915 - 450 pages
...inspector, free of cost, all reasonable facilities to satisfy him that the material is being furnished in accordance with these specifications. All tests...unnecessarily with the operation of the works. 16. (o) Unless otherwise specified, any rejection based on tests made in accordance with Section 5 shall...
Full view - About this book

The Design of Steam Boilers and Pressure Vessels

George Bartholomew Haven, George Wright Swett - Pressure vessels - 1915 - 450 pages
...manufacturer shall afford the inspector, free of cost, all reasonable facilities to satisfy him that the bars are being furnished in accordance with these...check analyses) and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not...
Full view - About this book

Transactions of the American Society of Mechanical Engineers, Volume 36

American Society of Mechanical Engineers - Mechanical engineering - 1915 - 1412 pages
...manufacturer shall afford the inspector, free of cost, all reasonable facilities to satisfy him that the bars are being furnished in accordance with these...check analyses) and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not...