Marine Fire Prevention, Firefighting and Fire Safety: A Comprehensive Training and Reference Manual (Google eBook)

Front Cover
DIANE Publishing, Jan 1, 1994 - Ships - 388 pages
3 Reviews
A comprehensive training and reference manual used as a textbook in maritime institutions. Addresses the prevention, control, and extinguishing of fires aboard commercial vessels and on offshore drilling rigs. Includes chapters on emergency procedures and equipment as well as case studies of past shipboard fires. Generously illustrated with drawings, photos, diagrams, tables, and checklists. Recommended reading for all maritime personnel and kept both in shipboard reference libraries and in the offices of maritime executives.
  

What people are saying - Write a review

User Review - Flag as inappropriate

Very useful in renewing my Chief Engineer's License

Contents

II
3
V
6
VI
7
VII
9
VIII
10
IX
11
X
12
XI
13
XCI
161
XCII
162
XCIII
170
XCIV
173
XCV
174
XCVI
181
XCVII
189
XCVIII
191

XII
16
XIII
17
XIV
18
XV
21
XVII
23
XIX
25
XXI
29
XXII
33
XXIII
36
XXIV
37
XXV
41
XXVII
43
XXVIII
45
XXIX
46
XXX
49
XXXI
51
XXXII
54
XXXIII
57
XXXIV
59
XXXV
62
XXXVI
68
XXXVII
69
XXXVIII
71
XL
72
XLI
75
XLII
76
XLIII
78
XLIV
80
XLV
81
XLVII
83
XLVIII
88
XLIX
95
L
97
LI
99
LII
101
LIII
102
LV
108
LVI
110
LIX
112
LX
115
LXII
118
LXIV
119
LXV
121
LXVII
124
LXVIII
130
LXIX
136
LXX
138
LXXI
139
LXXII
140
LXXIII
141
LXXVI
142
LXXVIII
143
LXXX
144
LXXXI
148
LXXXII
149
LXXXIII
152
LXXXIV
154
LXXXV
155
LXXXVIII
156
XC
159
XCIX
193
C
196
CI
197
CII
198
CIII
199
CV
200
CVI
206
CVII
209
CVIII
222
CIX
228
CX
229
CXI
231
CXIII
233
CXIV
236
CXV
238
CXVI
240
CXVII
247
CXVIII
249
CXX
251
CXXI
253
CXXII
257
CXXIII
259
CXXIV
261
CXXV
263
CXXVII
264
CXXVIII
267
CXXIX
268
CXXX
271
CXXXI
273
CXXXIII
274
CXXXIV
277
CXXXV
279
CXXXVI
283
CXXXVII
287
CXXXVIII
290
CXXXIX
294
CXL
297
CXLI
298
CXLII
303
CXLIII
311
CXLIV
315
CXLV
325
CXLVI
327
CXLVIII
331
CXLIX
335
CL
351
CLI
352
CLII
355
CLIV
357
CLV
358
CLVI
360
CLVII
361
CLVIII
363
CLX
365
CLXII
366
CLXV
367
CLXVI
368
CLXVIII
369
CLXIX
377

Common terms and phrases

Popular passages

Page 15 - Guard and the Occupational Safety and Health Administration (OSHA) of the Department of Labor, and the Minerals Management Service (MMS) of the Department of the Interior.
Page 197 - Except as noted in 193.15-20(b) , all controls and valves for the operation of the system shall be outside the space protected and shall not be located In any space that might be cut off or made inaccessible in the event of fire in any of the spaces protected. (b) If...
Page 16 - Section 2, Title II of the act of June 15, 1917, as amended, 50 USC 192, provides as follows: If any owner, agent, master, officer, or person in charge, or any member of the crew of any such...
Page 133 - ... per square metre of the area protected by the largest monitor, such area being entirely forward of the monitor, but not less than 1,250 //minute.
Page 165 - ... may be reached with at least 2 streams of water from separate outlets, at least one of which shall be from a single length of hose. In main machinery spaces, all portions of such spaces shall be capable of being reached by at least 2 streams of water, each of which shall be from a single length of hose from separate outlets; however, this requirement need not apply to shaft alleys containing no assigned space for the stowage of combustibles.
Page 183 - Spaces which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on board while the vessel is being navigated, other than paint and lamp lockers and similar small spaces, shall be fitted with an approved audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally located and shall be marked as required by...
Page 165 - ... under shut off condition is not capable of developing the pressure described in 108.415 plus 1.75 kilograms per square centimeter (25 pounds per square inch). (b) Each fire pump in a fire main system must have a pressure gauge on its discharge side. (c) Fire pumps may be used for other purposes. One of the required pumps must be kept available for use on the fire system at all times. If a fire pump is used in a system other than the fire main system, except for branch lines connected to the...
Page 165 - Q (Specifications) of this chapter. (d) Fire hydrants shall be of sufficient number and so located that any part of the vessel, other than main machinery spaces, accessible to...
Page 265 - Ship 7 short blasts and 1 long blast on the whistle and the same signal on the general alarm bells. Man Overboard Hail, and pass the word "Man Overboard
Page 16 - ... stowing, loading, discharging, or transporting any dangerous cargo covered by 126.27 under circumstances not covered by the general permit granted in 126.27 or when such general permit is not in force will subject persons responsible therefor to the penalties of fine and imprisonment provided in section 2, Title II of the act of June 15. 1917. as amended.