National Electrical CodeNational Fire Protection Association, 1959 - Electric engineering 1978 edition updated by: Tentative interim amendment 70-78-6 to the National electrical code, NFPA 70-1978; approved for release June 20, 1979. |
From inside the book
Results 1-3 of 67
Page 70-219
... lamps , arc lamps , electric discharge lamps , the wiring and equipment forming part of such lamps , fixtures and lighting installa- tions shall conform to the provisions of this Article , except as otherwise provided in this code . 410 ...
... lamps , arc lamps , electric discharge lamps , the wiring and equipment forming part of such lamps , fixtures and lighting installa- tions shall conform to the provisions of this Article , except as otherwise provided in this code . 410 ...
Page 70-370
... Lamps . Arc lamps shall comply with the fol- lowing : ( a ) Installation . Arc - lamp frames and standards shall be so installed and guarded as to prevent their becoming grounded . ( b ) General Construction . Portable arc lamps shall ...
... Lamps . Arc lamps shall comply with the fol- lowing : ( a ) Installation . Arc - lamp frames and standards shall be so installed and guarded as to prevent their becoming grounded . ( b ) General Construction . Portable arc lamps shall ...
Page 70-499
... Lamps ) Electric Discharge , 410 - P , 410 - Q Fluorescent , Art . 410 Guards , ( see Guarding and Guards ) Handlamps ( see Handlamps ) Incandescent , Art 410 Bases for , 410-49 As Resistors , 470-8 Infra - Red ( see Infra - Red Lamps ) ...
... Lamps ) Electric Discharge , 410 - P , 410 - Q Fluorescent , Art . 410 Guards , ( see Guarding and Guards ) Handlamps ( see Handlamps ) Incandescent , Art 410 Bases for , 410-49 As Resistors , 470-8 Infra - Red ( see Infra - Red Lamps ) ...
Contents
ARTICLE | 70-11 |
ARTICLE PAGE 90 Introduction 7011 | 70-13 |
General 100 Definitions 7014 | 70-14 |
Copyright | |
70 other sections not shown
Other editions - View all
Common terms and phrases
accessible alternating current ampere rating amperes appliances apply approved armored cable Article Asbestos Bonding jumpers branch circuit building busway cabinets Cambric capacitors carrying capacity cent circuit conductors circuit-breaker Code comply conform connected covering current-carrying capacity cutout boxes Dielectric Heat disconnecting means Dry locations ductors dumbwaiter electrical conductors electrical metallic tubing electrode enclosed enclosure exceed exposed feeder feet Fixture wiring flame-retardant flexible cord floor fuseholders fuses grounding conductor hazardous locations horsepower inches installed insulated conductors junction boxes lampholders lamps lighting lightning arrester material maximum metal raceways moisture motor neutral noncombustible Number of Conductors operating overcurrent device overcurrent protection Paragraph physical damage pipe plug portable receptacles resistors Rubber rubber-covered service conductors service equipment small appliance space specified suitable supply supported surface switchboard switches Table taps temperature terminals Thermoplastic transformers Type MI cable ungrounded unless voltage volts watts welder wet locations Wireways wiring method wiring system