Advances in Biomedical Engineering, Volume 1 |
From inside the book
Results 1-3 of 46
Page 20
manual guidance of the probe rather than electro - mechanical movement of the probe ( Donald et al . , 1958 ) . One of the most important problems in the development of satis- factory B - scanning equipment was the exact transfer of the ...
manual guidance of the probe rather than electro - mechanical movement of the probe ( Donald et al . , 1958 ) . One of the most important problems in the development of satis- factory B - scanning equipment was the exact transfer of the ...
Page 40
... probe has previously been carefully angled from a distance of 50 mm to obtain the maximum obtainable height in the reflected echo . Then , without alteration to the setting of the equipment , the probe and the reflector plate are placed ...
... probe has previously been carefully angled from a distance of 50 mm to obtain the maximum obtainable height in the reflected echo . Then , without alteration to the setting of the equipment , the probe and the reflector plate are placed ...
Page 41
... probe is read off without parallax . For each setting of the transmitter output of the equipment , with fixed maximum receiver amplification and lowest suppression level , is determined , with each probe , the distance between reflector ...
... probe is read off without parallax . For each setting of the transmitter output of the equipment , with fixed maximum receiver amplification and lowest suppression level , is determined , with each probe , the distance between reflector ...
Contents
Therapeutic Applications of Highintensity Ultrasound | 5 |
Ultrasonic Cleaning | 12 |
Ultrasonic Diagnosis with Continuous Waves | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
Acta action potentials amplitude analysis applied articular cartilage Ascenzi B-scan B-scan system behaviour bending test biological bone Buschmann cathode ray tube cell clinical collagen collagen fibres compressive Conf Connective Tissue crystal deformation Diagnostic Ultrasound diameter displacement dissimilarity number echogram echographic effect elastic elastin electron microscopy energy epoch error estimation Evans eyeball femur fibrils frequency GN/m² Haversian systems human increase intensity lamellae Langer's lines layer linear load longitudinal matched filter material maximum measurement mechanical properties method microscope MN/m² neural neuron noise normal obtained oil path Ophthalm osteocytes osteones output possible principal components probe procedure PSPs recorded response retina samples Scanning electron scanning electron microscopy Sedlin SIDUO-Kongressbericht signal skin sound beam specimens spike waveforms stress at fracture stress-strain curve structure surface technique tensile stress tension transducer tumour Ultrasonic Diagnosis Univ values of Young's variations vector wave waveform waveform separation Wiedau Young's Modulus Ztschr