Page 340
... coating : 1. Galvanizing . Hot - dip galvanizing of wire shall produce coating weights in accordance with Table No. 25-17 - U . 2. Mechanically deposited . Mechanically deposited zinc coating shall produce coating weights in accordance ...
... coating : 1. Galvanizing . Hot - dip galvanizing of wire shall produce coating weights in accordance with Table No. 25-17 - U . 2. Mechanically deposited . Mechanically deposited zinc coating shall produce coating weights in accordance ...
Page 545
... coating shall be applied by the electrostatic spray method and fully cured in accordance with the recommendations of the manufacturer of the coating material . Requirements for Coated Bars Sec . 26.418 . ( a ) Thickness of Coating . The ...
... coating shall be applied by the electrostatic spray method and fully cured in accordance with the recommendations of the manufacturer of the coating material . Requirements for Coated Bars Sec . 26.418 . ( a ) Thickness of Coating . The ...
Page 962
... coating shall not crack or flake when formed . The sheet steel shall be coated with not less than 0.55 ounce per square feet average of terne coating ( total both sides ) by triple spot test and not less than 0.40 oz./sq . ft . of terne ...
... coating shall not crack or flake when formed . The sheet steel shall be coated with not less than 0.55 ounce per square feet average of terne coating ( total both sides ) by triple spot test and not less than 0.40 oz./sq . ft . of terne ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone