National Electrical CodeNational Fire Protection Association, 1986 - Electric engineering 1978 edition updated by: Tentative interim amendment 70-78-6 to the National electrical code, NFPA 70-1978; approved for release June 20, 1979. |
From inside the book
Results 1-3 of 84
Page 70-40
... Receptacle outlets shall , insofar as practicable , be spaced equal distances apart . Receptacle outlets in floors shall not be counted as part of the required number of receptacle outlets unless located close to the wall . The ...
... Receptacle outlets shall , insofar as practicable , be spaced equal distances apart . Receptacle outlets in floors shall not be counted as part of the required number of receptacle outlets unless located close to the wall . The ...
Page 70-46
... outlets . Exception No. 1 : A receptacle installed solely for the electric supply to and support of an electric clock in any of the rooms specified above . Exception No. 2 : Outdoor receptacles . Exception No. 3 : In addition to the ...
... outlets . Exception No. 1 : A receptacle installed solely for the electric supply to and support of an electric clock in any of the rooms specified above . Exception No. 2 : Outdoor receptacles . Exception No. 3 : In addition to the ...
Page 70-532
... receptacle outlets in these rooms , and such circuits shall have no other outlets . Receptacle outlets supplied by at least two appliance receptacle branch circuits shall be installed in the kitchen . ( c ) General Appliances ...
... receptacle outlets in these rooms , and such circuits shall have no other outlets . Receptacle outlets supplied by at least two appliance receptacle branch circuits shall be installed in the kitchen . ( c ) General Appliances ...
Contents
Introduction | 70-1 |
Wiring Design | 70-27 |
Part E Service Equipment | 70-125 |
Copyright | |
2 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section aluminum ampacity amperes appliance apply approved assembly attachment plug bonding jumper branch circuit building busbars cable tray circuit breaker circuit conductors Class Code comply with Section connected connectors copper corrosive covered disconnecting means Division 2 locations electric conductors Electrical Ducts enclosure equipment grounding conductor exceed Exception exposed feeder feet fittings Fixture wiring flexible cord flexible metal conduit floor full-load current fuses ground-fault protection grounding electrode hazardous classified heater heating panel horsepower inches installed insulated conductors intermediate metal conduit junction box lampholders less lighting fixtures load marked maximum MC cable metal raceways multiconductor nameplate National Electrical Code NFPA number of conductors operating outlet box overcurrent device panelboard percent permitted in Section physical damage portable receptacle recreational vehicle service-entrance space specified Splices suitable supported surface switch switchboard Table temperature terminal Thermoset transformer Type ungrounded volt-amperes voltage volts wet locations wiring methods