...below the theoretical weight ; 75 inches wide up to 100 inches wide, 5 per cent above or 3 per cent below the theoretical weight. When 100 inches wide...above or 3 per cent below the theoretical weight. *********** (0) For all plates ordered to gauge there will be permitted an avonigo excess of weight... | |
| John Butler Johnson - Building materials - 1898 - 906 pages
...inches wide and over, 10 per cent above or 3 per cent below the theoretical weight. ********** (f) For all plates ordered to gauge, there will be permitted an average excess or weight over that corresponding to the dimensions on the order equal in amount to that specified... | |
| Cambria Steel Co - Building - 1901 - 448 pages
...below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above, or 3 per cent. below the theoretical weight. When 100 inches wide...above, or 3 per cent, below the theoretical weight. f. For all plates ordered to gauge, there will be permitted an average excess of weight over that corresponding... | |
| James Nisbit Hazlehurst - Tanks - 1901 - 258 pages
....either above or below the theoretical weight. Seventy-five inches and over, 5 per cent., either above or below the theoretical weight. • (c) For all plates...will be permitted an average excess of weight over than corresponding to the dimensions in the order equal in amount to that specified in the following... | |
| Albert Ladd Colby - Steel - 1902 - 114 pages
...below the theoretical weight. 75 inches wide up to loo inches wide, 5 per cent. above or 3 per cent. below the theoretical weight. When 100 inches wide...above or 3 per cent below the theoretical weight. AMERICAN STANDARD SPECIFICATION (»'). For all plates ordered to gauge, there will be permitted an... | |
| Albert Ladd Colby - Steel - 1902 - 114 pages
...below the theoretical weight. 75 inches wide up to loo inches wide, 5 per cent. above or 3 per cent. below the theoretical weight. When 100 inches wide...above or 3 per cent. below the theoretical weight. (g). For all plates ordered to gauge, there will be permitted an average excess of we1ght over that... | |
| American Society of Mechanical Engineers - Mechanical engineering - 1902 - 982 pages
...below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above or 3 per cent, below the theoretical weight. When 100 inches wide...above or 3 per cent, below the theoretical weight. * * * » * * * (g) For all plates ordered to gauge, there will be permitted an average excess of weight... | |
| John Butler Johnson - Engineering - 1902 - 600 pages
...below the theoretic;.! •weight ; 75 inches wide up to 100 inches wide, 5 per cent above or 3 per cent below the theoretical weight. When 100 inches wide and over, 10 per cent above or 8 per cent below the theoretical weight. *********** (.9) For all plates ordered to gauge there will... | |
| Robert Henry Thurston - Building materials - 1903 - 828 pages
...below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above or 3 per cent, below the theoretical weight. When 100 inches wide...above or 3 per cent, below the theoretical weight. ******** (z) For all plates ordered to gauge, there will be permitted an average excess of weight over... | |
| Harry Huse Campbell - Iron - 1903 - 914 pages
...below the theoretical weight, 75 inches wide up to 100 inches wide, •> per cent, above or 3 per cent, below the theoretical weight, When 100 inches wide and over, 10 per cent, above or 3 per cent, below !he theoretical weight, ******** (i) For all plates ordered to gauge, there will be permitted an average... | |
| |