Books Books 1 - 10 of 13 on Any and all blocks, samples of which, on being tested under the direction of the....
" Any and all blocks, samples of which, on being tested under the direction of the Bureau of Building Inspection, fail to stand at twenty-eight (28) days the tests required by this regulation, shall be marked " condemned" by the manufacturer or user, and... "
Cement Houses and how to Build Them: Illustrated Details of Construction ... - Page 17
by William A. Radford - 1909 - 170 pages
Full view - About this book

The manufacture of concrete blocks and their use in building construction

Harmon Howard Rice, William M. Torrance - Concrete blocks - 1905 - 122 pages
...forth in the "Standard Specifications for Cement" by the American Society for Testing Materials. 14. Any and all blocks, samples of which on being tested...the Bureau of Building Inspection, fail to stand at 28 days the tests required by this regulation, shall be marked condemned by the manufacturer or user...
Full view - About this book

Concrete-block Manufacture: Processes and Machines

Harmon Howard Rice - Concrete - 1906 - 152 pages
...forth in the " Standard Specifications for Cement " by the American Society for Testing Materials. 14. Any and all blocks, samples of which, on being tested...Building Inspection, fail to stand at twenty-eight days the tests required by this regulation, shall be marked " Condemned " by the manufacturer or user...
Full view - About this book

Concrete-block manufacture: processes and machines

Harmon Howard Rice - Concrete blocks - 1906 - 152 pages
...forth in the " Standard Specifications for Cement " by the American Society for Testing Materials. 14. Any and all blocks, samples of which, on being tested...Building Inspection, fail to stand at twenty-eight days the tests required by this regulation, shall be marked " Condemned " by the manufacturer or user...
Full view - About this book

Engineering Work in Towns and Cities

Ernest McCullough - Municipal engineering - 1908 - 502 pages
...dry sample) must not average higher than 15 per cent, and must not exceed 22 per cent in any case. CONDEMNED BLOCK. — Any and all blocks, samples of...by the manufacturer or user and shall be destroyed. CEMENT BRICK. —Cement brick may be used as a substitute for clay brick. They shall be made of one...
Full view - About this book

Proceedings of the Annual Convention, Volume 4

National Association of Cement Users (U.S.) - Concrete - 1908
...average higher than 15 per cent., and must not exceed 22 per cent, in any case. rondemnrt ^ny an{l ai| Blocks, samples of which, on being tested under the...twenty-eight (28) days the tests required by this regulation, sl1all be marked "condemned" by the manufacturer or user and shall be destroyed. K™kn' Cement brick...
Full view - About this book

Concrete Inspection: A Manual of Information and Instructions for Inspectors ...

Charles Shattuck Hill - Concrete - 1909 - 179 pages
...dry sample) must not average higher than 15 per cent, and must not exceed 22 per cent in any case. Any and all blocks, samples of which, on being tested...by the manufacturer or user and shall be destroyed. Cement brick may be used as a substitute for clay brick. They shall be made of one part cement to not...
Full view - About this book

Building construction and superintendence, Part 1

Frank Eugene Kidder - Building - 1909
...Specifications for Cement" by the American Society for Testing Materials. 14. Defective Blocks Condemned. — Any and all blocks, samples of which, on being tested...twenty-eight (28) days the tests required by this regulation, are to be marked "condemned" by the manufacturer or user, and are to be destroyed. 15. Inspection of...
Full view - About this book

The Building Code of the City of Manchester, New Hampshire: Final Enactment ...

Building laws - 1911 - 222 pages
...Specifications for Cement" by the American Society for Testing Materials. Sect. 418. Blocks Condemned— When Any and all blocks, samples of which on being tested under the direction of the Inspector of Buildings, fail to stand at twenty-eight days the tests required by these regulations,...
Full view - About this book

Compiled Ordinances of Detroit of 1912

Detroit (Mich.), Charles A. Nichols - Building construction - 1912 - 899 pages
...identification must be impressed in or otherwise permanently attached to each block. Sec. 13. CONDEMNED BLOCKS. Any and all blocks, samples of which on being tested under the direction of the Department of Buildings, fail to stand at twenty-eight (28) days, the test required by this Ordinance,...
Full view - About this book

Building Code: A Compilation of Building Regulations Covering Every Phase of ...

American School of Correspondence, Chicago, F. W. Fitzpatrick - Building laws - 1913 - 128 pages
...forth in the "Standard Specifications for Cement" by the American Society for Testing Materials. IlAny and all blocks, samples of which, on being tested under the direction of the Building Department, fail to stand (at twenty-eight days for concrete), the tests required by this...