Considerations about the Use of Computers in Radiodiagnostic Departments, Issue 16 |
From inside the book
Results 1-3 of 4
Page 8
... identity of the patient and the identity of the field to be treated , and the details will depend very much on the design of the individual system . There are two main methods by which data may be input : one uses pregenerated ...
... identity of the patient and the identity of the field to be treated , and the details will depend very much on the design of the individual system . There are two main methods by which data may be input : one uses pregenerated ...
Page 9
... set ( ii ) dose delivered ( 2 measurements in the case of double dosimetry ) ( iii ) time set ( iv ) time elapsed . ANCILLARY This covers various special items such as : - ( i ) identity of machine ( ii ) time and date ( iii ) name 9.
... set ( ii ) dose delivered ( 2 measurements in the case of double dosimetry ) ( iii ) time set ( iv ) time elapsed . ANCILLARY This covers various special items such as : - ( i ) identity of machine ( ii ) time and date ( iii ) name 9.
Page 10
... identity of radiographer identity of radiotherapist . The date and time in hours and minutes at which the treatment was actually given , could be useful in a system designed to check that a fractionation scheme was being rigidly adhered ...
... identity of radiographer identity of radiotherapist . The date and time in hours and minutes at which the treatment was actually given , could be useful in a system designed to check that a fractionation scheme was being rigidly adhered ...
Common terms and phrases
acceptable advanced techniques arc therapy automated procedures automated system Automatic Set-up B.Sc British Institute computer based computer control computer readable card Computers in Treatment consider Control of Treatment Convener COUCH PARAMETERS data input device discussed Dr R.E. Bentley dynamic treatment techniques experimental schemes gantry angle Hospital identified identity inhibit treatment input data Inst.P Institute of Radiology keyboard magnetic card MAIN WORKING PARTY Mark II MARK III MARK N.G. Trott necessary necessity for typing operating operating system optical override paper tape patient data PERMANENT RECORD Ph.D physicists position possible printer problems PROGRAMMED DYNAMIC TREATMENT Prospective checking punched card radiographers radiotherapy centre recording of dose reduction of mistakes Retrospective checking retrospective study set-up parameters specific staff subsequent arithmetic Sutherland task group TECHNOLOGY IN RADIOTHERAPY terms of reference therapy machine tolerance total automation treatment machine treatment planning treatment sheet Treatment Simulators Treatment Units United Kingdom visual display unit