| Chemistry - 1877 - 624 pages
...Prof. Abel's instructions for the application of the test are as follows : — The apparatus should be placed for use in a position where it is not exposed to currents of air. Ihe heating vessel or water-bath is filled by pouring water into its funnel until it begins to flow... | |
| Chemistry - 1877 - 608 pages
...Prof. Abel's instructions for the application of the test are as follows :— The apparatus should be placed for use in a position where it is not exposed to currents of air. The heating vessel or water-bath is rilled by pouring water into its funnel until it begins to flow... | |
| Chemistry - 1877 - 316 pages
...Prof. Abel's instructions for the application of the test are as follows : — The apparatus should be placed for use in a position where it is not exposed to currents of air. The heating vessel or water-bath is rilled by pouring water into its funnel until it begins to flow... | |
| Great Britain - 1879 - 472 pages
...the top, and ranges from about 55° F. to 150° F. ; it measures from end of ivory back to bulb 2£". NOTE. — A model apparatus is deposited at the Weights...position where it is not exposed to currents of air or draughts. 2. The heating vessel or water bath is filled by pouring water into the funnel until it begins... | |
| Great Britain. Parliament. House of Commons - Great Britain - 1879 - 610 pages
...20 top, and ranges from about 55° F. to 150° F. ; it measures from end of ivory back to bulb 2J". NOTE. — A model apparatus is deposited at the Weights...Trade. DIRECTIONS FOR APPLYING THE FLASHING TEST. 25 1. The test apparatus should be placed for use in a position where it is not exposed to currents... | |
| 1880 - 690 pages
...250° C. (=392° to 482° F.) Ph. Centralh. Directions for Applying the flashing Test to Kerosine Oil. 1. THE test apparatus is to be placed for use in a postion where it is not exposed to currents of air or draughts. 2. The heating vessel or water-bath... | |
| Great Britain, Edmund Humphrey Woolrych - Local government - 1880 - 966 pages
...the top, and ranges from about 55° F. to 150° F. ; it measures from end of ivory back to bolb Si». NOTE. — A model apparatus is deposited at the weights...of the board of trade. Directions for applying the Fiathing Test. 1. The test apparatus is to be placed for use in a position where it is not exposed... | |
| Great Britain, Edmund Humphrey Woolrych - Local government - 1880 - 940 pages
...the ton, and ranges from about 55° F. to 150" F. ; it measures from end of ivory back to bulb 2|". NOTE. — A model apparatus is deposited at the weights...measures department of the board of trade. Directions far applying tlie Flashing Test. 1. The test apparatus is to be placed for use in a position where... | |
| Railway clearing house - 1880 - 900 pages
...at the Weights and Measures Depamae: c: Board of Trade. DIRECTIONS FDR APPI.YINO THE FLASHING TBST. 1. The test apparatus is to be placed for use in a position where it is not expoad I currents of air or draughts. 2. The heating vessel or water bath is filled by pouring water... | |
| International health exhibition, 1884 - 1881 - 516 pages
...otherwise ordered by Parliament, and the extent of the repeal is set forth in another schedule. The model apparatus is deposited at the Weights and Measures Department of the Board of Trade. OPERATIVES' MEALS. The Home Secretary has extended the special prohibition of the Factory and Workshop... | |
| |