International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 91
Page 67
... ( inches ) For SI : 1 inch = 25.4 mm , 1 foot = 304.8 mm , 1 pound per square inch = 6.895 Pa . a . Mortar shall be ... 12 inches ( 305 mm ) of the wall , 2. Wall height shall not exceed 8 feet ( 2438 mm ) , 3. Height of unbalanced ...
... ( inches ) For SI : 1 inch = 25.4 mm , 1 foot = 304.8 mm , 1 pound per square inch = 6.895 Pa . a . Mortar shall be ... 12 inches ( 305 mm ) of the wall , 2. Wall height shall not exceed 8 feet ( 2438 mm ) , 3. Height of unbalanced ...
Page 106
... ( inches ) SPACING OF FASTENERS Edges ( inches ) Intermediate supports ( inches ) Wood structural panels subfloor ... 12 318 Staple 16 ga . 13/4 Staple 15 ga . 13 / g 0.097 - 0.099 Nail 111⁄2 6 12 4 10 Staple 16 ga . 13/4 6 12 Staple 15 ga ...
... ( inches ) SPACING OF FASTENERS Edges ( inches ) Intermediate supports ( inches ) Wood structural panels subfloor ... 12 318 Staple 16 ga . 13/4 Staple 15 ga . 13 / g 0.097 - 0.099 Nail 111⁄2 6 12 4 10 Staple 16 ga . 13/4 6 12 Staple 15 ga ...
Page 203
... ( inches ) MEMBERS ( inches o.c. ) Nailsa Screwsb Perpendicular 16 7 12 Either direction 16 8 16 Ceiling Either direction 16 7 12 Ceilingd Perpendicular 24 7 12 1/2 Wall Either direction 24 8 12 Wall Either direction 16 8 16 Ceiling ...
... ( inches ) MEMBERS ( inches o.c. ) Nailsa Screwsb Perpendicular 16 7 12 Either direction 16 8 16 Ceiling Either direction 16 7 12 Ceilingd Perpendicular 24 7 12 1/2 Wall Either direction 24 8 12 Wall Either direction 16 8 16 Ceiling ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel