Audels Engineers and Mechanics Guide, Volume 5

Front Cover
T. Audel & Company, 1921 - Steam engineering
 

Other editions - View all

Common terms and phrases

Popular passages

Page 2-21 - The inspector representing the purchaser shall have free entry, at all times while work on the contract of the purchaser is being performed, to all parts of the manufacturer's works which concern the manufacture of the material ordered.
Page 2-21 - The manufacturer shall afford the inspector, free of cost, all reasonable facilities to satisfy him that the rivets are being furnished in accordance with these specifications. All tests and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not to interfere unnecessarily with the operation of the works.
Page 2-224 - ... inside surface of the sheet. Stays through laps or butt straps may be drilled with larger hole to a depth so that the inner end of said larger hole shall not be nearer than the thickness of the boiler plates from the inner surface of the boiler.
Page 2-21 - Three bend and three flattening tests shall be made from each size in each lot of rivets offered for inspection, each of which shall conform to the requirements specified.
Page 2-19 - The yield point shall be determined by the drop of the beam of the testing machine.
Page 2-157 - ... an addition of 1 shall be made to the required percentage of reduction of area. The bend test specimen shall bend cold through 90°...
Page 2-156 - Statutes, and having a record thereof in the office of the local inspectors in the district where the boiler was built or intended to be used, may be used for marine purposes, notwithstanding that such boilers may have been used for other purposes, if in the judgment of the local inspectors they are deemed safe.
Page 2-222 - DIAGONAL, AND GUSSET STAYS Multiply the area of a direct stay required to support the surface by the slant or diagonal length of the stay; divide this product by the length of a line drawn at right angles to surface supported to center of palm of diagonal stay. The quotient shall be the required area of the diagonal stay.
Page 2-191 - The distance between the center lines of any two adjacent rows of rivets, or the "back pitch" measured at right angles to the direction of the joint, shall be at least twice the diameter of the rivets and shall also meet the following requirements: a Where each rivet in the inner row comes midway between two rivets in the outer row, the sum of the two diagonal sections of the plate between the inner rivet and the two outer rivets...
Page 2-22 - J in. above the jaws, and the projecting end broken off by light blows of a hammer, the bending being away from the groove. The specimen shall be broken at the other two grooves in the same manner. The object of this test is to open and render visible to the...

Bibliographic information