Adequate Wiring for Home and FarmA clear and simple explanation of the basic principles of wiring and the materials and methods of installation. |
From inside the book
Results 1-3 of 30
Page 123
... fixture wiring ( new fixtures ) . Check against wiring diagram . e ) Low room temperature ( below 50 deg . F. ) . Fluorescent lamps often fail to start when very cold . ( The best room temperatures lie between 60 and 90 deg . F. ) . Use ...
... fixture wiring ( new fixtures ) . Check against wiring diagram . e ) Low room temperature ( below 50 deg . F. ) . Fluorescent lamps often fail to start when very cold . ( The best room temperatures lie between 60 and 90 deg . F. ) . Use ...
Page 196
... fixture must be supported by an outlet box , a fixture stud or strap is required ( for clarity these are not shown in Fig . 145 , nor is a box hanger ) . A fixture stud is best for support of a wall - bracket type of fixture ; for ceiling ...
... fixture must be supported by an outlet box , a fixture stud or strap is required ( for clarity these are not shown in Fig . 145 , nor is a box hanger ) . A fixture stud is best for support of a wall - bracket type of fixture ; for ceiling ...
Page 219
... fixture wiring , but if the test lamp has gone out the short is elsewhere . Test the other fixtures on that circuit . Of course the wall switches should be closed for each fixture . 4. To test an appliance , plug it into its usual ...
... fixture wiring , but if the test lamp has gone out the short is elsewhere . Test the other fixtures on that circuit . Of course the wall switches should be closed for each fixture . 4. To test an appliance , plug it into its usual ...
Contents
Preface Acknowledgment vii | 1 |
Electrical Terms and Principles | 6 |
Adequate Wiring | 24 |
Copyright | |
15 other sections not shown
Common terms and phrases
aluminum amperes Amps appliance circuits areas basement branch circuits bulbs cable capacitor ceiling Chapter circline circuit breakers Code Article Code Table coils conduit connected cooling copper cord drier equipment farm wiring Farmstead Wiring feeders fixture floor fluorescent lamps foot-candles fustat grounded neutral grounding conductor heat pump home and farm installed insulation Interior Wiring kilowatts larger length line drop line wires listed load center low voltage lumens main switch metal meter motor N. E. Code nameplate National Electrical Code neoprene nonmetallic operation outdoor outlet box overcurrent protection overload percent plug fuse portable relay service drop service entrance service panel service-entrance single-phase sockets speed split-phase standard starter temperature thermoplastic three-phase three-way switches three-wire tubes two-wire two-wire circuits Type Underwriters Laboratories usually utility room valance voltage drop volts wall receptacles wattage watts wire sizes wiring system yard pole