Handbook of Basic Microtechnique |
From inside the book
Results 1-3 of 63
Page 175
... placed at the bottom of the inner glass funnel and the material that is to be searched for mites is placed loosely on this gauze . The lower end of the glass funnel is attached with modeling clay to a tube containing whatever medium is ...
... placed at the bottom of the inner glass funnel and the material that is to be searched for mites is placed loosely on this gauze . The lower end of the glass funnel is attached with modeling clay to a tube containing whatever medium is ...
Page 191
... placed on the upper sheet of glass . The whole should now be left for at least 12 hr before removing the glass and ... placed in an exceedingly weak solution and allowed to absorb the stain slowly than placed in a strong solution that ...
... placed on the upper sheet of glass . The whole should now be left for at least 12 hr before removing the glass and ... placed in an exceedingly weak solution and allowed to absorb the stain slowly than placed in a strong solution that ...
Page 194
... placed over the smear . It is rather difficult to see the trophozoite stages in an unstained preparation , but no difficulty will be experienced in pick- ing out the spore cases ( pseudonavicellae ) because of their relatively high ...
... placed over the smear . It is rather difficult to see the trophozoite stages in an unstained preparation , but no difficulty will be experienced in pick- ing out the spore cases ( pseudonavicellae ) because of their relatively high ...
Contents
Principles of Microscopy | 3 |
The Use of the Microscope | 21 |
Photomicrography | 40 |
Copyright | |
16 other sections not shown
Common terms and phrases
70 per cent absolute alcohol acid agent angle appear balsam become better block blue cause cell cent alcohol Chapter clean clear color completely containing coverslip cytoplasm dehydrating described desired differentiation distilled water dried drop edge embedding embryo employed examined example field filter fixative fluid given glass hand hardened hematoxylin iris knife lamp least leave lens less light manner material medium method microscope microtome mixture mounted natural necessary nuclei object obtained ocular operation paraffin passed permit placed possible prefer preparation preserved produce recommended relatively remain removed ribbon Rinse running sections seen selected shown in Fig shows side slide smear solution specimen stage stain staining solution substage sufficiently surface taken technique temperature thick tion tissues transferred tube usually washed whole wholemounts xylene